Adaptive Randomised Control Trial
Summary:
Any randomised controlled trial design that features an interim analysis used to review and potentially modify the trial design in key ways. These modifications ensure a more efficient trial overall.
Full Description:
An adaptive trial allows for the conduct of interim analyses that may result in the subsequent change in trial design in specific pre-planned ways. These changes can often include changes in sample size and makeup, dosage, early conclusion of treatment stages or incorporation of other measures. Other adaptations can involve randomising fewer participants to less promising treatment arms or recruiting more or less participants to attenuate the power of the study. These changes ensure a more efficient study process overall, potentially benefitting current and future participants and saving money.
However, there are number of unique challenges posed by adaptive trial designs. Concluding a treatment arm due to futility may be triggered by a false positive interim result. It may also result in fewer participants in the concluded treatment arm, resulting in sample size imbalances thus affecting the power to reach conclusions relating to primary and secondary measures or adverse effects. There may also be missed opportunities in observing participants for longer periods of time. Furthermore, to receive the full benefits from early stopping of treatment arms, the interim analysis needs to be concluded efficiently. This implies efficient data management procedures coupled with good communication pathways between the Data Safety and Monitoring Board, the trial investigation team and field researchers.
Adaptive designs require more meticulous pre-planning, with specific criteria determining under what circumstances the trial might be modified. This is crucial to allow prospective participants to understand fully what participation might involve and how involvement might change over time and from a practical perspective, to allow an external and independent Data Safety and Monitoring Board (DSMB) to analyse interim data and recommend changes appropriately.

Statistical Code:
- Pallmann P, Bedding AW, Choodari-Oskooei B et al. Adaptive designs in clinical trials: why use them, and how to run and report them. BMC medicine BMC Med. 2018;16:29. 10.1186/s12916-018-1017-7
- Bhatt DL, Mehta C. Adaptive Designs for Clinical Trials. The New England journal of medicine The Changing Face of Clinical Trials N Engl J Med. 2016;375:65-74. 10.1056/NEJMra1510061
- Savitz and their team investigated the use of aspirin, minocycline, placebo and both aspirin and minocycline in the augmented treatment of bipolar depression. Initially, 120 participants (30 to each study arm), however an interim analysis conducted once 60 participants had been recruited and treated suggested that the aspirin + placebo and the minocycline + placebo arms could be concluded. The participants allocated to these arms were reallocated to either the placebo + placebo or the aspirin + minocycline arms instead. Savitz JB, Teague TK, Misaki M et al. Treatment of bipolar depression with minocycline and/or aspirin: an adaptive, 2×2 double-blind, randomized, placebo-controlled, phase IIA clinical trial. Translational psychiatry Transl Psychiatry. 2018;8:27-11. 10.1038/s41398-017-0073-7
- Freeman and colleagues investigated several levels of dosage of cannabidiol in the treatment of cannabis use disorder. The primary outcome measure was urinary creatinine levels and/or days abstinent. An interim analysis was pre-planned after outcome measures were obtained for the initial sample size of n=12 per arm. This lead to the low dose arm (200mg) being dropped from further investigation and additional recruitment of participants then randomised to the remaining three arms (i.e.. placebo, 400mg and 800mg) in stage II. Freeman TP, Hindocha C, Baio G et al. Cannabidiol for the treatment of cannabis use disorder: a phase 2a, double-blind, placebo-controlled, randomised, adaptive Bayesian trial. Lancet Psychiatry. 2020;7:865-874. 32735782 10.1016/S2215-0366(20)30290-X